An energy-efficient algorithm for wearable electrocardiogram signal processing in ubiquitous healthcare applications

  • Ali Hassan Sodhro*
  • , Arun Kumar Sangaiah
  • , Gul Hassan Sodhro
  • , Sonia Lohano
  • , Sandeep Pirbhulal
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

78 Citations (Scopus)

Abstract

Rapid progress and emerging trends in miniaturized medical devices have enabled the un-obtrusive monitoring of physiological signals and daily activities of everyone’s life in a prominent and pervasive manner. Due to the power-constrained nature of conventional wearable sensor devices during ubiquitous sensing (US), energy-efficiency has become one of the highly demanding and debatable issues in healthcare. This paper develops a single chip-based wearable wireless electrocardiogram (ECG) monitoring system by adopting analog front end (AFE) chip model ADS1292R from Texas Instruments. The developed chip collects real-time ECG data with two adopted channels for continuous monitoring of human heart activity. Then, these two channels and the AFE are built into a right leg drive right leg drive (RLD) driver circuit with lead-off detection and medical graded test signal. Human ECG data was collected at 60 beats per minute (BPM) to 120 BPM with 60 Hz noise and considered throughout the experimental set-up. Moreover, notch filter (cutoff frequency 60 Hz), high-pass filter (cutoff frequency 0.67 Hz), and low-pass filter (cutoff frequency 100 Hz) with cut-off frequencies of 60 Hz, 0.67 Hz, and 100 Hz, respectively, were designed with bilinear transformation for rectifying the power-line noise and artifacts while extracting real-time ECG signals. Finally, a transmission power control-based energy-efficient (ETPC) algorithm is proposed, implemented on the hardware and then compared with the several conventional TPC methods. Experimental results reveal that our developed chip collects real-time ECG data efficiently, and the proposed ETPC algorithm achieves higher energy savings of 35.5% with a slightly larger packet loss ratio (PLR) as compared to conventional TPC (e.g., constant TPC, Gao’s, and Xiao’s methods).

Original languageEnglish
Article number923
JournalSensors (Switzerland)
Volume18
Issue number3
DOIs
Publication statusPublished - 2018-Mar-20
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Swedish Standard Keywords

  • Electrical Engineering, Electronic Engineering, Information Engineering (202)

Keywords

  • Beats per minute (BPM)
  • Electrocardiogram (ECG) signal processing
  • Energy-efficiency
  • ETPC
  • Filters
  • Healthcare
  • Noise
  • Ubiquitous
  • Wearable platform

Fingerprint

Dive into the research topics of 'An energy-efficient algorithm for wearable electrocardiogram signal processing in ubiquitous healthcare applications'. Together they form a unique fingerprint.

Cite this