T1 - An In Vivo Investigation of Non-Metallic vs. Metallic Hand Scalers on Zirconia Implant-Supported Crowns
T2 - A Year-Long Analysis of Peri-Implant Maintenance
AU - Roemermann, Dayna L.
AU - Atout, Reem
AU - Pesun, Igor
AU - Kelekis-Cholakis, Anastasia
AU - Stavropoulou, Chrysi
AU - Renvert, Stefan N.
AU - França, Rodrigo
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/12/23
Y1 - 2023/12/23
N2 - This study examined whether the degree of abutment surface modification that may occur with regular periodontal instrumentation has a clinical impact in terms of increased plaque accumulation and increased peri-implant tissue inflammation on zirconia implant abutments. Thirteen patients who had zirconia implant crowns were recruited in this randomized clinical trial. Each patient acted as their control and had either the buccal or lingual surface of their screw-retained implant restoration scaled with a metallic scaler and the other surface with a non-metallic scaler at 3, 6, 9, and 12 months. Cytokine testing of the peri-implant crevicular fluid was completed at 0, 3, and 12 months for IL-2, IL-4, IL-6, IL-8, IL-10, TNF-α, or IFNγ. Implant crowns were removed at 12 months and evaluated under an atomic force microscope for the average roughness (Ra). The implant crowns were polished and re-inserted. The results were analyzed using the Kruskal–Wallis test, and post hoc tests were conducted with a significance level of α = 0.05. Significant differences in surface roughness (Ra) were observed between the metallic and non-metallic scalers. The median Ra values were 274.0 nm for metallic scalers and 147.1 nm for non-metallic scalers. However, there were no significant differences between the type of scaler used and the amount of clinical inflammation or cytokine production. Metallic scalers produced deeper, more aggressive surface alterations to the abutment/crown zirconia surface, but there was no statistically significant difference between the degree of surface alterations, amount of BOP, and the amplitude of cytokine inflammation produced.
AB - This study examined whether the degree of abutment surface modification that may occur with regular periodontal instrumentation has a clinical impact in terms of increased plaque accumulation and increased peri-implant tissue inflammation on zirconia implant abutments. Thirteen patients who had zirconia implant crowns were recruited in this randomized clinical trial. Each patient acted as their control and had either the buccal or lingual surface of their screw-retained implant restoration scaled with a metallic scaler and the other surface with a non-metallic scaler at 3, 6, 9, and 12 months. Cytokine testing of the peri-implant crevicular fluid was completed at 0, 3, and 12 months for IL-2, IL-4, IL-6, IL-8, IL-10, TNF-α, or IFNγ. Implant crowns were removed at 12 months and evaluated under an atomic force microscope for the average roughness (Ra). The implant crowns were polished and re-inserted. The results were analyzed using the Kruskal–Wallis test, and post hoc tests were conducted with a significance level of α = 0.05. Significant differences in surface roughness (Ra) were observed between the metallic and non-metallic scalers. The median Ra values were 274.0 nm for metallic scalers and 147.1 nm for non-metallic scalers. However, there were no significant differences between the type of scaler used and the amount of clinical inflammation or cytokine production. Metallic scalers produced deeper, more aggressive surface alterations to the abutment/crown zirconia surface, but there was no statistically significant difference between the degree of surface alterations, amount of BOP, and the amplitude of cytokine inflammation produced.
KW - cytokines
KW - dental implants
KW - peri-implant maintenance
KW - surface roughness
KW - zirconia