TY - JOUR
T1 - Leachability testing of metallic wastes
AU - Svensson, Britt-Marie
AU - Mårtensson, Lennart
AU - Mathiasson, Lennart
AU - Eskilsson, Linda
PY - 2005
Y1 - 2005
N2 - The performance of two tests, a batch test and a percolation test for the characterization of waste as suggested in the EU council decision 2003/33/EC was investigated. The tests were carried out on two solid waste streams from a metal recycling industry. The concentrations of heavy metals such as Cu, Znand Pb were more than one order of magnitude lower than the proposed limit values. Generally, batch test values were equal or higher than percolation test values. With the proposed test procedures both materials could be considered as non-dangerous wastes. The test performance was also investigated using a leachant with higher ionic strength instead of demineralized water as prescribed. The results clearly show a significant increase in the concentration of some heavy metals. Total concentrations of phenolic compounds and polychlorinated biphenyls were less than 1 p.p.m. and 2 p.p.b., respectively. The precision of the batch and the percolation tests were on average 48 and 35%, respectively.
AB - The performance of two tests, a batch test and a percolation test for the characterization of waste as suggested in the EU council decision 2003/33/EC was investigated. The tests were carried out on two solid waste streams from a metal recycling industry. The concentrations of heavy metals such as Cu, Znand Pb were more than one order of magnitude lower than the proposed limit values. Generally, batch test values were equal or higher than percolation test values. With the proposed test procedures both materials could be considered as non-dangerous wastes. The test performance was also investigated using a leachant with higher ionic strength instead of demineralized water as prescribed. The results clearly show a significant increase in the concentration of some heavy metals. Total concentrations of phenolic compounds and polychlorinated biphenyls were less than 1 p.p.m. and 2 p.p.b., respectively. The precision of the batch and the percolation tests were on average 48 and 35%, respectively.
KW - Leachability tests
KW - leachate water
KW - metallic waste
KW - risk assessment.
KW - waste characterization
U2 - 10.1177/0734242X05058684
DO - 10.1177/0734242X05058684
M3 - Article
SN - 0734-242X
VL - 23
SP - 457
EP - 467
JO - Waste Management & Research
JF - Waste Management & Research
IS - 5
ER -